Ecotermix 300 (60) PRO G1

ETM 300 (60) PRO G1 is a two-component system for producing rigid thermal insulation polyurethane foam by spraying onto building structures.

Blowing agentWater
System weight, kg470
Yield per set, m³6 – 6.5
Apparent density, kg/m³55 – 65
Application temperature, °Cfrom + 10
Mix ratio A:B (by volume)100:100
Packaging
100 kg220 kg
Request a quote

Description

ETM 300 (60) PRO G1 is a two-component system for producing rigid thermal insulation polyurethane foam by spraying onto building structures. When component A (polyol) is mixed with component B (polymeric MDI) in a PU foam spraying unit, a chemical foaming reaction occurs, forming a rigid closed-cell foam with a density of 60 kg/m³. The cured coating performs reliably across a temperature range from –40 °C to +300 °C, making the system a sought-after solution for thermal protection of steam and process pipelines, industrial equipment, tanks and metal structures. Flammability class G1 confirms the material's compliance with fire safety requirements for oil and gas, power generation and industrial facilities.

The PRO series features an increased concentration of active components in the polyol, providing improved thermal insulation properties of the cured foam while reducing system consumption on site. The closed-cell structure of the polyurethane foam ensures low thermal conductivity, high adhesion to metal, concrete and other substrates, as well as additional protection against corrosion and moisture ingress. The spray application method allows uniform coverage of surfaces of any geometry - flanges, elbows, tees, weld seams - without cutting or fitting the material. The quality of the system is confirmed by testing to the international standards ASTM D 4889 and ASTM D 891.

Features and benefits of ETM 300 (50) PRO G1

ETM 300 (60) PRO G1 is not just a thermal insulation coating, but a multifunctional professional-grade protective coating.

  • Extreme temperature range
    The operating range from –40 °C to +300 °C covers the vast majority of industrial applications - from insulating cold storage rooms to insulating steam pipelines and industrial furnaces. The coating does not crack, delaminate or lose adhesion under sharp temperature fluctuations.
  • Flammability class G1 - low flammability material
    The formulation meets the fire safety requirements of industrial and civil facilities. Class G1 means the coating does not sustain combustion or spread fire, which is critical for oil and gas, power generation and production facilities.
  • Thermal conductivity of 0.03 W/(m·K)
    One of the best values among liquid thermal insulation coatings. Achieved through a high content of microspheres with vacuumed air inside the formulation. A coating of just 2-3 mm already provides a noticeable thermal insulation effect.
  • Vapour barrier and condensation protection
    The coating has low vapour permeability, preventing condensation from forming on surfaces with temperature differentials. This is particularly relevant for cold pipelines, ductwork and structures in high-humidity environments.
  • Application to surfaces of any geometry
    The liquid form allows coverage without losses of flanges, elbows, tees, weld seams and other hard-to-reach areas - where installing board or roll materials is physically impossible or requires significant labour.
  • PRO series - reinforced formulation
    Compared to the standard ETM lineup, the PRO series contains a higher concentration of thermal insulation components. This delivers a higher effect with fewer layers and reduces the overall material consumption on site.

Advantages over alternatives

  • Operating temperature up to +300 °C - most standard liquid thermal insulation materials are rated for +120–150 °C, and PU foam shells cannot withstand above +110 °C. Ecotermix 300 (60) PRO G1 is suitable for hot steam and process pipelines without the need to change materials.
  • Application to surfaces of any geometry - flanges, elbows, tees and weld seams are coated by brush or spray gun without the cutting and fitting required for mineral wool and PU foam shells.
  • Flammability class G1 - low flammability - most competing liquid formulations are class G2 or do not declare a fire classification at all. PU foam shells belong to class G3–G4.
  • Built-in corrosion protection - the alkaline environment of the formulation (pH 12) passivates metal and prevents under-film corrosion. When using mineral wool and PU foam, a separate anti-corrosion layer is required.
  • High installation speed - application is completed in a single work shift without scaffolding, clamps or fasteners. Installing mineral wool mats and shells is considerably more labour-intensive.
  • Simple maintenance and repair - a damaged area is restored by spot application with a brush. Repairing board and roll materials requires dismantling entire sections.
  • Minimal load on the structure - a coating thickness of 2–5 mm adds practically no weight to the insulated object, unlike mineral wool mats and rigid shells.
  • Work on operating equipment - application is possible without stopping production. Installing rigid insulation in most cases requires taking the equipment out of service.
  • Compliance with international standards - the formulation has been tested to ASTM D 4889 and ASTM D 891, which is important for facilities with foreign technical supervision and international project documentation.

How to order ETM 300 (60) PRO G1

To check the current price and purchase the professional liquid thermal insulation system, submit a request on the website or contact our sales team. The product is supplied ready for use - the formulation is fully prepared for application and does not require mixing components on site, eliminating dosing errors during work. Special wholesale terms are available for contractors and companies with large volumes of thermal insulation work.

Specifications

Component ratio

Name Parts by weight
Component A ETM 300 (60) PRO G2 100
Component B Polymeric MDI (PMDI) 105

Physical properties

Units Component Method
Dynamic viscosity mPa·s 300–800 (25°C) GOST 1929-87, ASTM D 4889
Density kg/cm3 1000–1250 (25°C) GOST 18995.1-73, ASTM D 891
Shelf life months 12

Reaction characteristics under recommended conditions*

Value
Appearance Liquid, white to yellow in colour, stratification is allowed
Cream time, s 2 – 7
Rise time, s 8 – 18
Apparent density under free rise, kg/m³ 55 – 65⁴
Appearance of cured polyurethane foam and structure on vertical cross-section (visual) Rigid foamed material. Fine-cell structure with a small number of larger cells
Thermal conductivity, W/m·K ≤ 0.03
Water absorption (24 h), % 2 – 5
Flammability class G1

*The data refer to tests carried out in accordance with the manufacturer's documentation using a laboratory mixer. Component temperature – 25±0.5°C, mixer speed – 2000 rpm. Mixing time – 5 s.

Shelf life

12 months from the date of manufacture when stored in a hermetically sealed container. After the shelf life has expired, the product may be used following verification of compliance with the requirements of this technical documentation.

Equivalents

Equivalents of the «ETM 300 (60) PRO G1» spray polyurethane foam system include two-component PU foam systems from other manufacturers with a similar flammability class G1 and density - for example, formulations based on rigid closed-cell spray polyurethane foam with an operating temperature of up to +300 °C and a thermal conductivity in the range of 0.028–0.035 W/m·K. When choosing between materials, it is recommended to check with a technical specialist regarding processing conditions, equipment requirements, component availability and compatibility with the specific site and substrate type.

Need a quote or technical advice?