Request a quote

Ecotermix 300 (50) F THERMO G2

ETM 300 (50) F THERMO G2 is a two-component system for producing heat-resistant closed-cell spray polyurethane foam (SPF), designed to create seamless thermal insulation for hot surfaces, industrial equipment and building structures. The material is designed for continuous operation at temperatures from –60 to +150 °C and withstands short-term exposure of up to +180 °C. The system is used for the thermal insulation of hot pipelines, tanks, heat exchangers, process equipment, boiler rooms, utility networks, as well as for insulating buildings, hangars, roofs and metal structures.

Blowing agentFreon
System weight, kg470
Yield per set, m³7 – 7.5
Apparent density, kg/m³45 – 55
Continuous operating temperature, °Cfrom -60 to +150
Mix ratio A:B (by volume)100:100
Packaging
100 kg220 kg
Request a quote

Description

ETM 300 (50) F THERMO G2 is a two-component system for producing heat-resistant closed-cell spray polyurethane foam (SPF), designed to create seamless thermal insulation for hot surfaces, industrial equipment and building structures. The material is engineered for continuous operation at temperatures from –60 to +150 °C and withstands short-term exposure to temperatures of up to +180 °C, making it suitable for applications where standard PU foam systems operate at the limits of their performance.

The system is used for the thermal insulation of hot pipelines, process vessels, tanks, heat exchangers, production equipment, boiler rooms, utility networks, as well as for insulating buildings, hangars, roofs and other structures. Closed-cell spray polyurethane foam forms a seamless insulating layer with high adhesion to metal, concrete, brick, wood and most construction materials, reducing heat loss and preventing cold bridges.

Freon is used as the blowing agent, which allows spraying of the polyurethane foam at ambient temperatures from –5 °C. This makes the system suitable for performing thermal insulation work in cold weather without a significant reduction in coating quality.

Features and benefits

• Heat-resistant polyurethane foam for high temperatures

The system is designed for facilities operating at elevated temperatures. The continuous operating temperature is up to +150 °C, and the material can withstand short-term heating up to +180 °C without a significant change in performance properties.

• Thermal insulation of hot pipelines and equipment

The material is used for the thermal insulation of pipelines, tanks, heat exchangers, process equipment, utility systems and other facilities where it is necessary to maintain the temperature of the process medium or reduce heat loss.

• Heat retention and reduced energy loss

Closed-cell heat-resistant PU foam reduces heat energy loss, helps maintain a stable temperature in process operations and lowers heating or equipment warming costs.

• Suitable for bathhouses and saunas

The system can be used to insulate bathhouses, saunas, ceilings, roofs and other structures, provided the temperature of the insulation layer itself does not exceed the material's permissible operating values. The seamless coating effectively retains heat inside the space and eliminates cold bridges.

• Spraying at sub-zero temperatures

The Freon-based system allows insulation work by spraying at ambient temperatures from –5 °C, which extends the construction season.

• Monolithic, seamless thermal insulation

After spraying, a single layer of closed-cell polyurethane foam is formed, eliminating joints and cold bridges and providing reliable thermal insulation for structures of complex shape.

Advantages over equivalents

  • heat-resistant polyurethane foam with an operating temperature of up to +150 °C;
  • allows thermal insulation of hot pipelines and industrial equipment;
  • suitable for maintaining the temperature of hot tanks and vessels;
  • spraying of PU foam is possible at ambient temperatures from –5 °C;
  • high adhesion to most construction materials;
  • low water absorption and closed-cell structure;
  • seamless thermal insulation with no cold bridges;
  • reduced heat loss and improved energy efficiency of facilities.

Specifications

Component ratio

Name

Mass fraction

Component A — ETM 300 (50) F THERMO G2

100

Component B — Polymeric MDI (PMDI)

105

Physical properties of components

Parameter

Units

Value

Method

Dynamic viscosity

mPa·s

300–600 (25 °C)

GOST 1929-87 / ASTM D4889

Density

kg/m³

1000–1250 (25 °C)

GOST 18995.1-73 / ASTM D891

Shelf life

months

12

—

Reaction characteristics under recommended conditions*

Parameter

Value

Appearance

Liquid, white to yellow in colour; stratification is acceptable

Cream time, s

2–7

Rise time, s

10–30

Apparent density at free rise, kg/m³

45–55

Appearance of cured PU foam

Rigid foamed material with a fine-cell structure

Thermal conductivity, W/(m·K)

≤ 0.03

Water absorption (24 h), %

2–5

Flammability class

G2

* Data refer to laboratory testing at a component temperature of 25±0.5 °C, a mixing speed of 2000 rpm and a mixing time of 5 s. Actual values depend on processing conditions.

Shelf life

The shelf life of the ETM 300 (50) F THERMO G2 system is 12 months from the date of manufacture, provided the components are stored in sealed factory containers and the recommended storage conditions are observed. To preserve the performance properties of the two-component spray polyurethane foam system, the material must be protected from moisture, direct sunlight and extreme temperatures.

After the specified shelf life has expired, the PU foam components do not necessarily lose their performance properties. The material may be used after verifying compliance with the technical documentation requirements and confirming that the required physical and chemical characteristics have been retained. Before use, it is recommended to carry out incoming inspection and a trial foaming run, especially if the system is intended for critical spray polyurethane foam or industrial insulation work.

Equivalent products

Equivalents to the ETM 300 (50) F THERMO G2 spray polyurethane foam system include two-component SPF systems from other manufacturers with a similar flammability class G1 and density — for example, Elastospray 1612, Khimtrast SKN-40 and other closed-cell rigid spray polyurethane foam formulations with an operating temperature of up to +150 °C and a thermal conductivity in the range of 0.028–0.035 W/(m·K). When choosing between materials, it is recommended to consult a technical specialist regarding processing conditions, equipment requirements, component availability and compatibility with the specific project and substrate type.

Need a quote or technical advice?

Tell us about your application, volumes and destination. Our team will reply with a proposal and technical data sheets.

Request a quote