Ecotermix 300 (40) NORT G3
Two-component freon-blown system of flammability class G3 for spraying rigid PU foam. Seamless coating with thermal conductivity of 0.020-0.025 W/m·K, applicable from -16 °C. Suitable for roofs, façades, walls, floor/ceiling slabs, cold storage and warehouse facilities, tanks and industrial equipment.
| Blowing agent | Freon |
| Yield per set, m³ | 8.5 – 9.5 |
| Apparent density, kg/m³ | 35 – 45 |
| Application temperature, °C | from -16 |
| Mix ratio A:B (by volume) | 100:100 |
| System weight, kg | 470 |
Description
ETM 300 (40) NORT G3 is a professional two-component system for spraying polyurethane foam (PU foam), designed to provide reliable thermal insulation for buildings, structures, warehouse facilities and industrial equipment. The material forms rigid polyurethane foam with a fine-cell structure, low thermal conductivity and stable performance characteristics.
The system is used for insulating roofs, façades, walls, floor/ceiling slabs and floors, as well as cold storage rooms, warehouse facilities, tanks and process equipment. ETM 300 (40) NORT G3 is suitable for construction and industrial applications where effective sprayed thermal insulation is required, with the ability to apply at reduced temperatures.
Features and benefits of ETM 300 (40) NORT G3
ETM 300 (40) NORT G3 is a modern spray polyurethane foam system developed for creating a rigid thermal insulation layer on facilities of various types. The material combines ease of processing, low thermal conductivity, moisture resistance and the ability to be used under demanding temperature conditions.
- Low thermal conductivity of 0.020 - 0.025 W/m·K, ensuring effective heat retention.
- Forms a seamless thermal insulation layer without cold bridges.
- Rigid, fine-cell structure with a small number of larger cells.
- Fast cream time of 2 - 7 seconds and foam rise time of 10 - 20 seconds.
- Can be applied at ambient temperatures from -16 °C to +35 °C.
- Reduced sensitivity to mixing of component A when storage and preparation conditions are followed.
- Low water absorption of 2 - 5%, improving the moisture resistance of the insulation layer.
- Flammability class G3 for use on construction and industrial sites.
- Suitable for use with both high- and low-pressure spray equipment.
- Apparent free-rise density of 35 - 45 kg/m³.
Thanks to these properties, the system is widely used for thermal insulation of roofing structures, façades, floors, walls, building envelopes, cold storage rooms and tanks. The sprayed PU foam forms a dense coating that follows the shape of the substrate and helps reduce heat loss at the facility.
Advantages over alternatives
ETM 300 (40) NORT G3 compares favourably with standard PU foam systems due to its ability to be applied at sub-zero temperatures, stable foam structure and ease of processing. The system is suitable for contractors and companies that need predictable results when applying rigid spray polyurethane foam.
- Can be applied at temperatures down to -16 °C, extending the application season.
- Low thermal conductivity of 0.020 - 0.025 W/m·K for efficient thermal insulation.
- Fine-cell structure of the rigid PU foam, ensuring stability of the insulation layer.
- Reduced risk of cold bridges due to seamless application.
- Reduced sensitivity to mixing of component A, simplifying material preparation.
- Compatible with standard equipment used for applying rigid PU foam systems.
- Used for construction, warehouse and industrial insulation.
- Optimal density, water absorption and flammability class for professional use.
As a result, using ETM 300 (40) NORT G3 helps create reliable, long-lasting thermal insulation, improve the energy efficiency of a facility and reduce heat loss. The material is particularly relevant for projects where rigid polyurethane foam needs to be sprayed under low-temperature conditions.
How to buy ETM 300 (40) NORT G3
To check the current price and purchase the two-component spray polyurethane foam system ETM 300 (40) NORT G3, please submit a request on the website. The system is supplied in sets: component A - polyol blend and component B - polymeric MDI (PMDI). The recommended mix ratio during processing is 100:105 by weight.
Special terms and favourable offers are available for contractors, construction companies and businesses carrying out thermal insulation work when purchasing in bulk.
Specifications
Component ratio
| Name | Mass part | |
| Component A | ETM 300 (40) NORT G3 | 100 |
| Component B | Polymeric MDI (PMDI) | 105 |
Physical properties
| Unit | Component | Method | |
| Dynamic viscosity | mPa·s | 300–800 (25ºC) | GOST 1929-87, ASTM D 4889 |
| Density | kg/cm3 | 1000–1250 (25ºC) | GOST 18995.1-73, ASTM D 891 |
| Shelf life | months | 12 |
Reaction characteristics under recommended conditions*
| Value | |
| Appearance | Homogeneous liquid, light brown to dark brown, without visible foreign inclusions |
| Cream time, s | 2 – 7 |
| Foam rise time, s | 10 – 20 |
| Apparent free-rise density, kg/m³ | 35 – 45 |
| Appearance of cured polyurethane foam and structure on vertical cross-section (visual) | Rigid foamed material. Fine-cell structure with a small number of larger cells |
| Thermal conductivity, W/m·K | 0.020 – 0.025 |
| Water absorption (24 h), % | 2 – 5 |
| Flammability class | G3 |
*Data relate to tests carried out in accordance with the manufacturer's documentation using a laboratory mixer. Component temperature – 25±0.5°C, mixer speed – 2000 rpm. Mixing time 5 s.
Shelf life
Storage conditions
- Components of the ETM 300 (40) NORT G3 system must be stored in enclosed warehouse facilities at temperatures from 15 °C to 30 °C, in tightly sealed containers that prevent the ingress of moisture, contaminants and direct sunlight.
Drums should be stored with the bungs facing up, at a distance of at least 1 m from heating appliances.
Warranty and shelf life
The shelf life of the system is 12 months from the date of manufacture, provided storage conditions are observed. After the shelf life has expired, the product may be used after verifying compliance with the requirements of the technical documentation.
Alternatives
ETM 300 (40) NORT G3 is similar in its characteristics to freon-blown rigid spray polyurethane foam systems from manufacturers such as Khimtrast, Izolan, BASF Elastopor, Huntsman Daltotherm and others. These materials are also used for seamless spray-applied thermal insulation and provide low thermal conductivity, a stable foam structure and coating durability.
At the same time, these systems may differ in foam density, reaction times, flammability class, as well as recommended processing temperatures and application conditions. For ETM 300 (40) NORT G3, the apparent free-rise density is 35-45 kg/m³, the thermal conductivity is 0.020-0.025 W/m·K, the flammability class is G3, and the minimum permissible ambient application temperature is -16 °C. The choice of a specific PU foam system depends on the project requirements, thermal insulation needs, operating conditions and the equipment used.
Related products

Ecotermix 300 (20) PRO G3
Blowing agent: Water System weight, kg: 470 Yield per set, m³: 17 – 21 Flammability class: G3 Application temperature, °C: from +10 Apparent density,
Details →
Ecotermix 300 (60) PRO THERMO G1
Blowing agent: Water System weight, kg: 470 Yield per set, m³: 6 – 6.5 Continuous operating temperature, °C: –60 to +150 Flammability class: G1 Appare
Details →
Ecotermix 300 (40) PRO THERMO G1
Blowing agent: Water System weight, kg: 470 Yield per set, m³: 8.5–9.5 Continuous operating temperature, °C: –60 to +150 Flammability class: G1 Appare
Details →
Ecotermix 300 (50) PRO THERMO G1
Blowing agent: Water System weight, kg: 470 Yield per set, m³: 7 – 7.5 Continuous service temperature, °C: –60 to +150 Flammability class: G1 Apparent
Details →Need a quote or technical advice?
Tell us about your application, volumes and destination. Our team will reply with a proposal and technical data sheets.