Request a quote
Bestseller

Ecotermix 300 (30) F G3

Two-component system for spraying rigid polyurethane foam (PU foam) Ecotermix 300 (30) F G3, designed for thermal insulation of construction and industrial facilities. Forms a durable, seamless coating with a fine-cell structure, low thermal conductivity, and stable density. Provides high adhesion to various substrates, moisture resistance, energy efficiency, and long-lasting insulation performance even when working at low temperatures.

Blowing agentFreon
Yield per set, m³10–12
System weight, kg470
Apparent density, kg/m³24–35
Application temperature, °Cfrom -5
Mix ratio A:B (by volume)100:100
Packaging
220 kg
Request a quote

Description

Ecotermix 300 (30) F G3 is a professional two-component spray polyurethane foam (SPF) system designed to create reliable thermal insulation for buildings, structures, and industrial equipment. The material forms a rigid polyurethane foam with a fine-cell structure, providing low thermal conductivity, high adhesion, and a long service life of the coating.

The system is used for insulating roofs, facades, walls, floor slabs, as well as cold storage rooms, warehouses, and tanks. It is suitable for both civil construction and industrial applications requiring effective thermal and water insulation.

Features and benefits of Ecotermix 300 (30) F G3

Ecotermix 300 (30) F G3 is a modern spray polyurethane foam system designed for efficient thermal insulation of facilities of various purposes. The material combines stable physical properties, ease of processing, and high energy efficiency.

  • Low thermal conductivity of 0.022–0.026 W/m·K, ensuring effective heat retention.
  • Forms a seamless insulation layer without thermal bridges.
  • Rigid fine-cell structure with high strength and stability.
  • Fast cream time (2–5 seconds) and rise time (10–20 seconds), speeding up the application process.
  • High adhesion to various types of substrates.
  • Can be applied at ambient temperatures as low as -5 °C.
  • Low water absorption (2–5%), increasing moisture resistance.
  • Suitable for use with both high-pressure and low-pressure equipment.
  • Stable foam density of 24–35 kg/m3 at free rise.

Thanks to these characteristics, the system is widely used in construction and industry, enabling reliable and durable thermal insulation with minimal operating costs.

Advantages over equivalents

Ecotermix 300 (30) F G3 compares favourably with standard PU foam systems due to the stability of its properties, ease of processing, and adaptation to real-world construction and industrial conditions. The material delivers predictable results and a high-quality insulation layer.

  • More stable foam structure with uniform cell distribution.
  • Lower thermal conductivity compared to most standard PU foam systems.
  • Fast reaction, reducing the time required to complete the work.
  • Can be applied at low temperatures without loss of quality.
  • Improved adhesion to various surfaces without additional primers.
  • Optimal balance of material density and strength.
  • Reduced risk of thermal bridging due to seamless application.
  • Versatile application for construction and industrial tasks.

As a result, using Ecotermix 300 (30) F G3 improves the energy efficiency of a facility, reduces operating costs, and provides a more durable thermal insulation solution compared to traditional materials.

How to buy Ecotermix 300 (30) F G3

To check the current price and purchase the Ecotermix 300 (30) F G3 two-component spray polyurethane foam system, please submit a request on the website. The system is supplied in sets (component A + polymeric MDI) at a mix ratio of 100:105 by weight, ensuring a stable reaction and high-quality formation of the PU foam layer.

Special terms and favourable offers are available for contractors, construction companies, and enterprises performing thermal insulation work when purchasing in bulk.

Shelf life

Storage conditions

  • The components of the Ecotermix 300 (30) F G3 system must be stored in enclosed warehouse premises at a temperature from 15 °C to 30 °C, in tightly sealed containers that prevent the ingress of moisture, contamination, and direct sunlight.

Drums should be stored bung-up, at a distance of at least 1 m from heating appliances.

Warranty and shelf life

The shelf life of the system is 12 months from the date of manufacture, provided it is stored in tightly sealed containers. After the shelf life has expired, the product may be used following verification of compliance with the requirements of the technical documentation.

Specifications

Component ratio

Name Mass fraction
Component A Ecotermix 300 (30) F G3 100
Component B Polymeric MDI (PMDI) 105

Physical properties

Unit Component Method
Dynamic viscosity mPa·s 300–600 (25ºC) GOST 1929-87, ASTM D 4889
Density kg/cm3 1000–1250 (25ºC) GOST 18995.1-73, ASTM D 891
Shelf life months 12

Reaction characteristics under recommended conditions*

Value
Appearance Homogeneous liquid, light green to dark green in colour
without visible foreign inclusions
Cream time, s 2–5
Foam rise time, s 10–20
Apparent density at free rise, kg/m³ 24–35⁴
Appearance of cured polyurethane foam and structure on vertical cross-section (visual) Rigid foamed material. Fine-cell structure with a minor amount of enlarged cells
Thermal conductivity, W/m·K 0.025–0.029
Water absorption (24 h), % 2–5
Flammability class G3

*The data refers to tests carried out in accordance with the manufacturer's documentation using a laboratory mixer. Component temperature – 25±0.5°C, mixer rotation speed – 2000 rpm. Mixing time 5 s.

Equivalents

Ecotermix 300 (30) F G3 is similar in performance to other spray rigid polyurethane foam systems, such as Khimtrast SKN30/141, Huntsman, BASF, and others. These materials are also used for seamless thermal insulation by spraying and provide low thermal conductivity and high adhesion.

However, these systems may differ in foam density, reaction time, flammability class (G3 for Ecotermix 300 (30) F G3), as well as recommended processing temperature ranges and application conditions. The choice of a specific PU foam system depends on the project objectives, thermal insulation requirements, operating conditions, and the equipment used.

Need a quote or technical advice?

Tell us about your application, volumes and destination. Our team will reply with a proposal and technical data sheets.

Request a quote